Product Manual
Page 8 of 13
Important: Use appropriate screws for framework and wall conditions.
2. To mount the shutter assembly, use the eight pre-punched 1/4" x 1/2" slotted mounting holes of
the shutter assembly to attach the unit to the framework.
3. Attach fan to installation wall surface as follows for applicable wall structure:
A. Wood Structure - Use 1/4’’ lag screws of appropriate length through each mounting hole.
B. Steel Structure - Use 1/4’’ bolt of appropriate length for application, in combination with a
1/4’’ flat washer and a 1/4’’ nut.
C. Masonry Structure - Use 1/4’’ lag screws in combination with a lag shield or equivalent 1/4’’
masonry fastener of appropriate length.
Note: The above mentioned hardware for mounting fans to wall surfaces is not provided by the
manufacturer since each mounting application is different. However, these items can be obtained from
your local hardware store.
4. This unit is equipped with a speed selector switch, which allows you to select a desired amount of
air delivery. Connect power to the motor, using the appropriate wiring method. (see Wiring
Diagram). Place all connections inside junction box.
Note: Be sure that when mounted, the shutter louvers open upward and close downward.
Wiring Diagram
Before Each Use
⚠WARNING