Product Manual
Page 4 of 13
Intended Use
This Strongway Shutter Exhaust Fan is designed for exhaust and circulation of indoor air to the
outside area.
Technical Specifications
Item#
Size
Voltage
Speeds
Watts / Amps
CFM / RPM
52847
12”
120
3
85/0.75
840 /1620
52848
16”
120
3
245/2.1
2100 /1620
52849
20”
120
2
250/2.2
2930/1000
52850
24”
120
2
255/2.2
3450/1000
52851
30”
120
2
290/2.9
4665 /1000
Important Safety Information
⚠WARNING
Read and understand all instructions. Failure to follow all instructions may result in serious injury
or property damage.
The warnings, cautions, and instructions in this manual cannot cover all possible conditions or
situations that could occur. Exercise common sense and caution when using this fan. Always be
aware of the environment and ensure that the fan is used in a safe and responsible manner.
Do not allow persons to operate or assemble the fan until they have read this manual and have
developed a thorough understanding of how it works.
Do not modify this fan in any way. Unauthorized modification may impair the function and/or safety
and could affect the life of the product. There are specific applications for which the product was
designed.
Use the right fan for the job. DO NOT attempt to force small equipment to do the work of larger
industrial equipment. There are certain applications for which this equipment was designed. It will
do the job better and more safely at the capacity for which it was intended. DO NOT use this
equipment for a purpose for which it was not intended.
Industrial or commercial applications must follow OSHA requirements.
⚠WARNING
This product may contain chemicals known to the State of California to cause cancer, birth defects or
other reproductive harm.
⚠WARNING
WORK AREA SAFETY
Inspect the work area before each use. Keep work area clean, dry, free of clutter, and well-lit.
Cluttered, wet, or dark work areas can result in injury. Using the fan in confined work areas may
put you dangerously close to cutting tools and rotating parts.