#53065 Property
#53065 Specification
AC Power Output
AC Power Voltage
115V
Maximum AC Output Power
750W
Maximum AC Output Surge Power
1500W
AC Output Frequency
58Hz - 62Hz
AC Output Waveform
Modified Sine Wave
USB Power Output
DC Output Voltage
5V DC, 2 Ports Shared 3.1 Amps Output
DC Power Specification
DC Input Voltage Range
11V to 15V DC
Battery Drain without AC Load
≤ 0.4A (at a 12V input)
Low Battery Shut-Down Point (Nominal)
10.5 ± 0.3V DC
High Battery Shut-Down Point (Nominal)
15.5 ± 0.5V DC
Efficiency (Maximum)
85%
Ambient Operating Temperature Range
32°F to 104°F
Important Safety Information
⚠WARNING
Read and understand all instructions. Failure to follow all instructions may result in serious injury
or property damage.
The warnings, cautions, and instructions in this manual cannot cover all possible conditions or
situations that could occur. Exercise common sense and caution when using this inverter. Always
be aware of the environment and ensure that the tool is used in a safe and responsible manner.
Do not allow persons to operate or assemble the inverter until they have read this manual and
have developed a thorough understanding of how it works.
Do not modify this inverter in any way. Unauthorized modification may impair the function and/or
safety and could affect the life of the product. There are specific applications for which the product
was designed.
Use the right tool for the job. DO NOT attempt to force small equipment to do the work of larger
industrial equipment. There are certain applications for which this equipment was designed. This
product will be safer and do a better job at the capacity for which it was intended. DO NOT use
this equipment for a purpose for which it was not intended.
Industrial or commercial applications must follow OSHA requirements.
⚠WARNING
This inverter may contain chemicals known to the state of California to cause cancer, birth defects
or other reproductive harm.
⚠WARNING
WORK AREA SAFETY
Inspect the work area before each use. Keep work area clean, dry, free of clutter, and well-lit.
Cluttered, wet, or dark work areas can result in injury. Using the inverter in confined work areas