Product Manual
Wiring Optional Accessories
DUAL SWING GATE OPENER
OWNER’S MANUAL
25 of 26
DUAL SWING GATE OPENER
OWNER’S MANUAL
24 of 26
Actuator 1
Actuator 2
Alarm Lamp (optional)
Back-up Battery (optional)
Photocell Beam System
(PBS) (optional)
Edge Sensor (optional)
Push Button (optional)
Loop Detector (optional)
Pull-to-Open
RED to MOTOR1+
BLACK to MOTOR1-
BLUE to ULT1
GREEN to COM
YELLOW to DLT1
Pull-to-Open
RED to MOTOR2+
BLACK to MOTOR2-
BLUE to ULT2
GREEN to COM
YELLOW to DLT2
Push-to-Open
BLACK to MOTOR1+
RED to MOTOR1-
YELLOW to ULT1
GREEN to COM
BLUE to DLT1
Push-to-Open
BLACK to MOTOR2+
RED to MOTOR2-
YELLOW to ULT2
GREEN to COM
BLUE to DLT2
Terminal ConnectionsAccessory
Connect the RED wire to terminal 11 and the WHITE wire to terminal 12.
Recommend strongly to use the solar controller to connect Battery
with battery’s Terminal of control board if the battery is used as the
primary power supply in system.
The STRONGWAY series gate opener can accept input from normal
closed output safety beam. A 2-wired photo beam with normal closed
dry-contact output can be directly connected to terminals 15 and 16,
no matter the polarity.
A 4-wired photo beam can be used with the gate opener. Terminals 9
and 14 are used to provide the power (24VDC) to the photo beam,
terminal 9 is positive and terminal 14 is negative.
Terminals 15 and 16 are used to accept the input signal from the
photo beam.
The STRONGWAY series gate opener can accept input from normal
closed output edge sensor. A 2-wired edge sensor with normal closed
dry-contact output can be directly connected to terminals 17 and 18,
no matter the polarity. Multiple sensors can be connected to the
terminals in series.
Use a 2-core cable to connect the pushbutton to the "O/S/C" terminal,
no need to consider the polarity.
Insert the Loop Detector Board into the Control Board, and then
connect the Loop Detector wires to the Control Board. For detailed
instructions, refer to the Loop Detector instruction manual.