Product Manual

21 of 26
Step 8 — Set the Gate Closed/Open Position
Note: Perform Step 8 for each gate opener.
The amount of extension of the gate opener's push-pull rod determines how much the gate
closes in a Pull-to-Open installation or how much the gate opens in a Push-to-Open installation.
Pull-to-Open Installation — If the push-pull rod is not extended enough, the gate will not
completely close. If it is extended too much, the gate may reverse and open after closing.
Push-to-Open Installation — If the push-pull rod is not extended enough, the gate will not
completely open. If it is extended too much, the gate may reverse and close after opening.
To set the push-pull-rod extension, attach the power cable to the gate opener. Use a
screwdriver to loosen the screw of Limit Switch B, slide Limit Switch B to the desired position,
and then tighten the screw. Use the remote control to open and close the gate. Adjust Limit
Switch B until the gate closes/opens properly.
Notes
• Sliding Limit Switch B toward the Gate Bracket increases the amount of push-pull rod extension.
• The position of Limit Switch A is factory set and should not be changed.
• Always place the Magnetic Ring between Limit Switch A and Limit Switch B.
Operation
• With the gate in its closed position, press and release the remote control, the gate will move
to the programmed opening position and stop.
• With the gate in its opened position, press and release the remote control, the gate will move
to the programmed closing position and stop.
• While the gate is moving, press and release the remote control, the gate will stop moving
immediately. The next command from the remote will reverse the gate direction and the gate
will stop at its programmed opening/closing position.
• The gate will reverse in case of obstruction or stall force during opening or closing.
The LED Display shows the status of the gate openers.The right LED shows the status of Gate
Opener 1 and the left LED shows the status of Gate Opener 2.(Gate Opener 1 is connected to
MOTOR 1 and Gate Opener 2 is connected to MOTOR 2)
• When Gate Opener 1 is running, the right LED displays n (gate opening) or u (gate closing).
• When Gate Opener 2 is running, the left LED displays n (gate opening) or u (gate closing).
• When Gate Opener 1 or Gate Opener 2 is not running, its LED displays – – (standby).
Emergency Release
DUAL SWING GATE OPENER
OWNER’S MANUAL
20 of 26
In case of a system failure or power outage, the gate can be
manually opened and closed. Open the release hole plug on
the top of the gate opener, insert the release key, and turn
the key 90° clockwise. This releases the motor and allows
the push-pull rod to move freely. To restore normal operation,
turn the key 90° counterclockwise.
DUAL SWING GATE OPENER
OWNER’S MANUAL
Controlling the Speed of the Gate
The gate opener operates at two factory set speeds: fast and slow. When the gate opens or
closes, the gate opener first operates at the slow speed for a user-specified number of seconds
(the Soft Start Period), then it operates at the fast speed for a user-specified number of seconds
(the Fast Running Period), and finally it operates at the slow speed for a number of seconds (the
Soft Stop Period) until the gate is fully opened or closed. The Soft Stop Period is not an option
that you can specify directly, it is determined by the Soft Start Period and the Fast Running
Period. To increase the Soft Stop Period, decrease either (or both) the Soft Start Period or the
Fast Run Period. To decrease the Soft Stop Period, increase either (or both) the Soft Start
Period or the Fast Run Period.
Control
Stall Force
Maximum Motor
Running Time
(MRT)
Safety Photocell
Beam System
Automatic
Closing Time
Soft Start Period
(STP)
Fast Running
Period (FRP)
Return to
Factory Settings
Code
P5
(Opener 1)
P6
(Opener 2)
P7
(Opener 1)
P8
(Opener 2)
P9
P10
Pb
Pc
Pd
Value
1 to 9
1 = minimal force
9 = maximum force
Default = 3
1 to 50 seconds
Default = 40
seconds
00 = OFF
11 = ON
Default = 00
1 to 99 seconds
Default = 60
seconds
0 to 9 seconds
Default = 3 seconds
1 to 28 seconds
Default = 15
seconds
Description
Stall Force is the amount of force that the
gate opener will apply to an object that is
obstructing the gate. When the specified
force is reached, the gate opener
automatically stops and reverses direction.
The gate opener’s opening/closing force is
adjusted automatically according to the
stall force setting.
MRT is the maximum length of time that
the gate opener will run. When the
specified MRT is reached, the gate opener
will stop running, even if the limit switch is
invalid or the clutch is detached.
A Safety Photocell Beam System is an
optional accessory. It is either turned ON or
turned OFF. If turned ON, the gate opener
will not work until the PBS system is
equipped.
Automatic Closing Time is the number of
seconds that the gate remains open before
it begins to close.
STP is the amount of time that the gate
opener operates at the slow speed when
the gate begins to open or close. See
Controlling the Speed of the Gate.
FRP is the amount of time that the gate
opener operates at the fast speed when
the gate is opening or closing. See
Controlling the Speed of the Gate.
To return all settings to their factory default,
press the FUNC button until the Digital
Display shows Pd, and then press the INC
button or the DEC button. The Digital
Display will now show dF, which indicates
that all settings were returned to their