Product Manual

DUAL SWING GATE OPENER
OWNER’S MANUAL
To erase all remote control commands: Press and hold the learn button until the LED display
“dL”,release the learn button the LED will display "- -". Now all remote codes have been erased.
Notes
• The maximum distance from which the remote control can operate the gate opener is 100 ft.
• The control box must be located so that transmission of signals are not obstructed or
impeded by building structures, natural landscaping, or similar obstruction.
Step 7 — Set Operating Controls
There are several controls that determine how the gate operates. Each control has a factory set
default, but it is recommended that each control be examined to ensure that it is set correctly
for the installation.
Each control has a code and range of numerical values (e.g., 1-9). The table below describes the
controls. You set the value of a control using the LED display and the FUNC, INC, and DEC buttons.
DUAL SWING GATE OPENER
OWNER’S MANUAL
To set a value for a control, follow these steps:
1. Apply power to the control board. The LED display will flash the standby symbol (– –).
2. Press and hold the FUNC button until the display shows P1. Each time you press the FUNC
button, the display will show the next code (e.g., P1, P2, P3, etc.).
3. Press the FUNC button until the code you want is displayed.
4. Press the INC or DEC button once. The display will show the current value of the control.
5. Press the INC or DEC button to set the desired value for the control. Each time you press the
INC button the numerical value increases by 1. Each time you press the DEC button, the
numerical value decreases by 1.
6. Press the FUNC button to save the value. The display will show the code for the next control.
7. If you want to set another control, press the FUNC button until the display shows the code
for the control that you want to set.
8. When you are finished setting controls, press the FUNC button until the display shows the
standby symbol (– –).
18 of 26 19 of 26
Control
Single/Dual
Primary/
Secondary
Open Interval
Close Interval
Code
P1
P2
P3
P4
Value
01 = single gate
(opener is connected
to MOTOR 1 on
Control Board)
10 = single gate
(opener is connected
to MOTOR 2 on
Control Board)
11 = dual gate
Default = 11
01 = opener
connected to MOTOR
1 on Control Board is
Primary
10 = opener
connected to MOTOR
2 on Control Board is
Primary
Default = 01
0 to 9 seconds
Default = 3 seconds
0 to 9 seconds
Default = 3 seconds
Description
(Dual gate only.) The Primary gate
opens first and closes last.
(Dual gate only.) Open Interval is the
amount of time that lapses from when
the Primary gate begins to open and
the Secondary gate begins to open. For
example, if the value is 3 seconds, the
Primary gate will begin to open 3
seconds before the Secondary gate
begins to open.
(Dual gate only.) Close Interval is the
amount of time that lapses from when
the Secondary gate begins to close and
the Primary gate begins to close. For
example, if the value is 3 seconds, the
Secondary gate will begin to close 3
seconds before the Primary gate begins
to close.