Step 5
Cut an electrical access hole in the cabinet(Figure E). If venting the unit through the horizontal knockout
plate or installing ductless, DO NOT cut a vertical duct access hole.
Then, install the 4 corner mounting screws halfway into the cabinet (Figure E). DO NOT tighten all the way,
and DO NOT install the 5th (middle) mounting screw. If the cabinets have recessed bottoms, install wood
shims prior to installing the screws.
Step 6
Lift the hood and tuck the power cable through the electrical access hole. Anchor the cable, but DO NOT
plug it in. Hang the hood from the 4 halfway-installed mounting screws in the cabinet. Slide the hood back
towards the wall until the mounting screw heads are locked in the narrow end of the keyhole slots in the top
of the hood. Tighten the screws securely. Then, add the 5th mounting screw in the center hole in the hood
and tighten securely.
Step 7
Ducted installation only. If installing ductless, skip this step.
Connect the ductwork to the hood, and secure the seam so that the unit is air tight. Reinstall the damper/duct
connector. Check that the ductwork is connected properly to the damper/duct connector, and that the damper
can open and close freely.
Step 8
Reinstall the filters, then plug in the unit. It is now ready for use.
Underside view of upper cabinets
VERTICAL DUCT
ACCESS HOLE
1"
11"
CENTER
LINE
HOOD MOUNTING SCREWS (5)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
CABINET
BOTTOM
2"
2"
11"
10"
13"(30" hood)
5"
3¼” X 10”
Vertical Ducting
13"(30" hood)
1
5
/
4
"
1
5
/
4
"
1
7
/
5
"
9"
POWER
CABLE
Figure E
Figure F
5 6