MSDS
Saft Rechargeable Battery Systems oct 2003
Ni-Cd Safety Data Sheet Page 2 of 7
2. COMPOSITION (Weight percentage of basic materials)
Single cell with steel container
Metals % Plastics % Other %
Iron Fe 25 - 37 Polyamide PA/PP 2.5 - 3.5 Potassium K/Na/Li 1.8 - 2.9
Nickel Ni 20 - 28 Rubber EPDM < 0.05 Water H2O 4 – 9
Cadmium Cd 10 - 15 Polyethylene PE 0.2 - 0.4 OH- 8 -14
Cobalt Co 0.4 -1.0 PVC 0.2 - 0.7
3. HAZARDS
A- Human hazards
A sealed Nickel-Cadmium cell is not hazardous in normal use.
3.1 Physical
Nickel plated steel can do not present any risk if cells are used for its intended purpose
and according to valid directions for use.
3.2 Chemical
Nickel plated steel can do not present chemical risk in normal use.
In case of misuse (abusive over charge, reverse charge, external short circuit…) and in
case of default, some electrolyte can leak from the cell through the safety vent.
In these cases refer to the risk of the Alcaline hydroxides.
The toxic properties of the electrode materials are hazardous only if the materials are
released by mechanical damaging the cell or if exposed to fire.
Classification of dangerous substances contained into the cells.
SUBSTANCES CLASSIFICATION
Name EEC Number
CAS Number
Symbol Letter Identification
of danger
Special risk
(1)
Safety
advice
(2)
Cadmium
Hydroxide
048-001-00-5
21041-95-2
Cd(OH)2 Xn Harmful R 20/21/22 S 22
Nickel
Hydroxide
028-008-x*
12054-48-7
Ni(OH)2 Xn Harmful R 20/22-43-40 S 22/36
Cobalt
Hydroxide
-
21041-93-0
Co(OH)2 Xn Harmful R22-42/43 S22-24-37
Alcalines
hydroxide
019-002-00-8
1310-58-3
KOH
NaOH
LiOH
C Corrosive R 35 S 26-37/39
-45