is cleared. Value range: 1-30 minutes. Default value: 1 Min.
3) Lock: specifies whether to lock alarm recordings. If this option is selected,
alarm recording will be locked once LDW alarm is triggered. The recording is
unlocked after the alarm is cleared.
4) Linkage IO output: The IO output volume can be configured after the IO
alarm is triggered. The IO output can be configured and used only when the
UPS power box is used (conventional power boxes do not provide IO outputs).
The duration for IP output can be configured, and the value range is 0 to 255
seconds. Note: AD Plus2.0 V1.1.0 does not support UPS power boxes.
5) Linkage Screen: specifies the screen to be displayed in live view after an
alarm is generated. By default, this parameter is set to None. You can also set
it to Single or Quad screen display.
6) Alarm Snap: specifies whether to capture images after an alarm is generated.
If an FTP address has been configured, channel capture will be enabled after
an IO alarm is generated, and captured images will be output via FTP. If alarm
evidence uploads parameters have been configured on the platform, captured
images can also be uploaded to the platform.
7) R-Watch Voice: Select or deselect this option to enable or disable the
R-Watch function. If this option is selected, R-Watch will play the beep alarm
sound and display the icon when the AD Plus2.0 connects to an R-Watch
peripheral and an alarm is triggered.
8) MP3 Voice: Select or deselect this option to enable or disable the MP3 voice
function. If this option is selected, the MDVR will play the MP3 alarm voice
when an alarm is triggered.
LDW
Tap Preferences > Alarm > AI App > ADAS. Enable LDW alarm. On the alarm
triggering setting screen, tap Setup to configure alarm parameters, as shown in the
following figure:
Comparing LDW alarm with HMW alarm, the setting screen has no duration and
comparing FCW alarm with HMW alarm, the setting screen has no sensitivity and
duration, with other setting parameters the same. Therefore, no more descriptions
are provided here.
It should be noted that, in the version V1.3, the sensitivity of LDW can only be
displayed and viewed but not set. For the requirement of setting, you need to send
commands remotely through the platform to modify it.