User's Manual

AD Plus2.0 User Manual
Page 59 of 66
of each alarm include the following and can be set as required. Speed range,
sensitivity, effective time (only one alarm is recorded when multiple alarms are
triggered within this time range), and duration (duration the alarm persists).
However, there are slight differences in the settable parameters of different alarms,
as shown in the following table:
Alarm Main
Type
Alarm Type
Settable Parameters
First-level and
Second-level
Speed
Distinction
Sensitivity Duration
Effective
Time
Linkage
ADAS
LDW Yes Yes None Yes Identical
FCW Yes None None Yes Identical
HMW Yes Yes Yes Yes Identical
PCW Yes None None Yes Identical
DMS/DSC Driver Fatigue Yes
Not
adjustable
None Yes Identical
No driver None Yes None Yes Identical
Handheld Devices Yes Yes None Yes Identical
Smoking Yes Yes None Yes Identical
Distraction Yes Yes None Yes Identical
Yawn Yes Yes None Yes Identical
Seatbelt Yes Yes None Yes Identical
No Mask Yes Yes None Yes Identical
Infrared Block
Alarm
Yes Yes None Yes Identical
BSD
Right blind spot
detection
None None Yes Yes Identical
Left blind spot
detection
None None Yes Yes Identical
Front blind area None None None Yes Identical
Since the parameter settings for all AI alarms are basically the same, the following
exemplifies how to set HMW alarm parameters. In addition, the No Driver alarm in
LDW/DMS alarms under the ADAS alarm is used as an example to show the
parameter setting differences between the LDW/DMS alarms and other alarms.
HMW
Tap Preferences > Alarm > AI App > ADAS. Select Enable for HMW, as shown
in the following figure: