User's Manual

AD Plus2.0 User Manual
Page 53 of 66
Panel Alarm: allows you to check the Panic Button to enable the panel alarm
and set alarm linkage parameters. On the Panic Trigger screen, you can set the
trigger time for pressing the button to trigger the panel alarm to 1–255s.
Default value: 1s (now it cannot be modified). Other parameters can be set in
the same way as for IO Alarm.
GPS Alarm: specifies alarms generated when GPS signals are lost. Parameters
can be set in the same way as for IO Alarm.
2.9.2. Video
Video Loss
On the Video Loss screen, you can set parameters for video loss alarms. Choose
Preferences > Alarm > Video > Video Loss and tap Setup in the Trigger column.
The Video Loss Trigger screen is displayed, as shown in the following figure: You
can specify the channel for which video loss alarms are generated. Alarm linkage
parameters can be set in the same way as for IO Alarm.