User's Manual Part 2
STRATEGIC Technologies Inc. Active Mode Installation
De-Installation / Removal
A. If your equipment is monitored by our Monitoring Center:-
- Fax the Inactivation Form to the Monitoring Center on the same day that the unit is to be
removed from the participant’s residence. It is important that the PRU+ does not continue to
call into the CC after the Inactivation form has been sent. If the PRU+ cannot be retrieved
from the residence have the participant disconnect the telephone cord until to can be picked
up.
B. If you monitor your own equipment:-
- Assure the participant‘s sentence ends on the same day that the unit is removed from the
participant’s residence.
1. Turn the PRU+ Off: Press and hold the PRU button on the LOCK until “Please Wait...” is
displayed on the PRU+. When “A=Turn PRU Off” is displayed, press button “A” on the PRU+.
Disconnect the AC power adapter from the standard 110 volt electrical outlet. The PRU+ will
turn off in approximately five seconds.
2. Disconnect the PRU+: Disconnect the AC power adapter from the back of the PRU+.
Disconnect the telephone cord from the PRU+ and wall jack. Place the PRU+, AC power
adapter and telephone cord into the carry / storage case.
3. Remove the Pin and slider bar: Using a tool such as a small screwdriver, rotate the locking
pin on the PID all the way around two times (in both directions). This will break the locking pin
and will enable the slider bar to be removed.
4. Remove the PID from the Baseplate: Remove the locking pin and slider bar. At the slider
bar end, lift the PID away from the baseplate (like opening a clam shell).
5. Remove the Battery: Remove the battery from the PID by pulling it out of the battery well and
place it in the plastic container in the carry / storage case. DO NOT TRY TO TURN THE
BATTERY.
6. Remove the strap: Remove the strap from the baseplate. Replace the baseplate back onto
the PID and return the PID to the carry / storage case.