User's Manual Part 4

STRATEGIC Technologies Inc. PRU / PID Preventive Maintenance
f. Watch for the PID code to appear in the right lower half of the display. This indicates the
PID is transmitting.
Returned Straps
1. Setup three cleaning containers as seen in Figure 8: Strap Cleaning. The first container has
soapy water. The second container has clean water. The third container has isopropyl
alcohol.
Figure 11 : Strap Cleaning
2. Place the dirty straps into the soapy water. Scrub the strap to remove any dirt/grime.
3. Once the strap is clean, rinse the strap in the clean water.
4. Disinfect the strap by placing it into the Isopropyl Alcohol. If Isopropyl Alcohol is not available,
spray the strap lightly with Lysol to disinfect.
5. To dry, hang the strap up or place on a paper towel.