User's Manual Part 3
STRATEGIC Technologies Inc. Special Function Mode
Special Function Mode
The PRU+'s Special Function Mode allows the installer to change various configuration settings,
clear the stored events, and enter a test / diagnostic mode. To enter the Special Function Mode,
you use the LOCK. Simply press the PRU+ button on the LOCK, while holding the LOCK
within three feet (1 metre) of the PRU+. The front panel display will show the message "Please
Wait....", and will then display two choices: "A=Turn PRU+ Off" and "B=Function Mode", as shown
below.
The PRU+ can be turned off by pressing the “A” button on the front display of the PRU+. Pressing
the "B" button will enter function mode. The first function mode screen is displayed, as shown
below.
Press the "B" button to clear all stored events in the PRU+'s memory. The display will prompt “A=**
Clear **”; press “A” to clear events. The message "Events Cleared!" will be displayed briefly.
Press the "A" button to move to the next screen.
Press “B” to enter the Quick Install function. Please refer to Quick Install on Page 44 for more
information. Press “A” to move to the next screen
Press the "B" button to enter Test Mode. Please refer to the section titled "Test Mode" on page 42.
Press the "A" button to move to the next screen.
This screen concludes the first set of program options. At this point, pressing the "B" button causes
the PRU+ to exit Special Function Mode and begin normal operation. Pressing the "A" button
returns the installer to the first screen (A=Turn PRU+ Off / B=Function Mode).
A-Turn PRU+ Off
B-Function Mode
A=Next FunctionB=Clear Events
A=Next FunctionB=Quick Install
A=Next FunctionB=Test Mode
A=Next FunctionB=EXIT