User's Manual Part 3

STRATEGIC Technologies Inc. Extended Special Function Mode
This screen enables the installer to limit the range the PRU+ will detect the presence of the PID. If
transmissions are received from the PID with a signal strength less than the value set the
transmission will be ignored. The value may be set between 0 - 255. A value of 0 indicates all
transmissions will be valid. To set the value press B and a cursor will appear under the first digit of
the setting. Press B to increment the current digit and press A to move to the next digit.
This screen allows the installer to change the number of the PID installed on the participant. This is
useful for cases where the supplied PID has been lost or broken, and a replacement PID with a
different code must be used. This screen operates similarly to the telephone number screen. When
this screen is displayed, pressing the "A" button will move to the next screen. If the "B" button is
pressed, a flashing cursor is displayed over the first character of the PID code. This indicates that
the display is now in "edit mode". While in “edit mode”, pressing the "B" button will change the
number under the cursor. Pressing the "B" button repeatedly will cycle the digit under the cursor
from 0 to 9. NOTE: code numbers such as "68" must be entered as "068". While in the edit mode,
pressing the "A" button steps through the digits from left to right, until the third digit is reached. At
this point, pressing the "A" button causes the screen to exit “edit mode” and move to the next
option.
This screen allows the installer to change the leave window for the PRU+. The leave window is the
period of time which the PRU+ allows to elapse without receipt of any transmissions from the PID
before a "Leave" message (ie ..info leave or ALARM AWAY) is registered. Pressing the "B" button
repeatedly steps through the possible values (3-30). Pressing the "A" button causes the next screen
to be displayed.
This screen allows the installer to change the code of the Domestic Violence Deterrent pendant (if
applicable) This setting allows the PRU+ to differentiate between the transmitter worn by the
offender and the pendant used by the victim. Different Alarm indications will be reported by the
PRU+ dependant on which code is received. See Individual Status Log Reports on Page 50 for
detailed explanations on these events.
A=Next FunctionB=Set RSSI 100
A=Next Function
B=Set PID# 30431
A=Next Function
B=Set Leave 03
A=Next FunctionB=SpsCode# 30253
A=Next FunctionB=DateFormat YMD