Full Product Manual

QUICKSCREEN PLUS BASE PLATE KIT
Contains components for 1x Base Plate:
COMPONENT QTY DETAILS
BASE PLATES 1 4” x 4 ½
SCREWS 4 12 G 3” countersunk screws
INLINE POST INSTALLATION
Requires 2-way posts for the middle of the fence run
and 1-way posts for each end of the fence run. Fencing
slats can be cut-back to create a shorter panel using the
following formula:
Required Slat length = ‘Post center distance’ minus 1”
CORNER POST LAYOUT
Requires one way posts and side frame kit. To adjust the
panel width between the post and the side frame kit, as
shown to the right, use the following formula:
Required Slat length = ‘Post Center Distance’ minus 2 ⁄
8’ 1 ⁄” (Using Standard Slats)
Sideframe
SIDE FRAME INSTALLATION
For use between existing structures or custom made posts.
Required slat length is calculated using the following
formula:
Required Slat length = Opening less 1”
GATE
Standard gates are 5’ 11’’ x 3’ 3 ½“ (H x W). Slats are spaced
at approx. ⁄” (9mm). To build a gate to a dierent width
use the following formulas:
Overall gate width = Outer edge to outer edge of gate side
frame
Required slat length = overall gate width minus 1 ⁄
(36mm)
Note: Please refer to your hinge kit details for gate opening
allowances.
QUICKSCREEN PLUS INSTALLATION DETAILS
Post Centers
(8’ Standard)
Post Centers
(8’ Standard)
8’ (Using Standard Slats)
Existing Wall Existing Wall
3’ 3 ⁄” (Using
Standard Slats)
5’ 11”