Objet1000 - Connex 2 User Guide
4. Select the UV lamp(s) to be replaced and click
Next
.
Figure 6-58: UV lamp selection screen
5. Disconnect the UV lamp power connector and the UV heat fuse
connector.
Figure 6-59: Disconnecting the UV lamp
Note: Do not disconnect the power connection to the cooling fans.
6. Loosen the screw securing the UV lamp cover
(A)
, and pull the cover
up
(B)
, then out
(C)
.
Figure 6-60: Removing the UV lamp cover