After examining the UV calibration results:
1. Click
Next
.
Figure 6-52: Final UV Calibration Wizard screen
Calibrating the
Load Cells
Load cells are sensors that measure the weight of the printing cartridges
and the waste container in the printer. It is important that you periodically
check that the weight measurements are accurate, both for convenience and
to prevent unnecessary waste of printing materials. It is recommended that
you calibrate the load cells once a month.
To calibrate load cells:
1. Start the Load Cell Calibration Wizard from the Options menu (see
figure 6 24 on page 25).
2. Make sure that there are no containers on the load cells that you want
to calibrate, select the appropriate check boxes in the wizard screen,
and click
Next
.
Figure 6-53: Load cell selection