12. In the wizard screen, confirm that the sensor is positioned correctly,
and click
Next
.
When you click
Next
, the UV lamps power up and stabilize. (This takes
several minutes.) Then, the print block passes over the sensor and
Figure 6-50: UV measurement progress
13. When prompted by the wizard, zero (reset) the UV meter and enter the
reading (measurement).
If the UV level measured is not acceptable, the wizard calibrates the UV
lamp by adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the
condition of the lamps after calibration.
Figure 6-51: Results and condition of UV lamps after calibration