User's Manual

DOC-06800 Rev. A
6–15
Objet1000 - Connex 2 User Guide
Cartridge
positioning
By default, Automatic slot selection determines the best positioning for the
material containers, based on materials currently in the system. This
ensures minimum flushing of materials currently loaded. If there is a
special need to load material containers in certain docks in the printer,
select
Manual slot selection
.
After clicking
Apply
, the Material Replacement Options screen appears, but
now, each material selection box corresponds to one of the container
positions in the printer.
Figure 6-13: Manual container positioning
Flush Again The flushing cycle you select in the Material Replacement Options screen
determines how thoroughly to flush out material currently in the system.
After selecting the Economy cycle and completing the wizard, you may
decide that you require a more thorough flushing, to ensure accurate
model color. Or, you may notice that printed models are not satisfactory
because they contain traces of the previous material. If so, you can flush out
more material, so that the next models will be printed with pure material.
After selecting the flush again option and clicking
Apply
, the Material
Replacement Options screen appears, where you select the affected
material(s) to be flushed.
Note: Select only the materials you need to flush.