User's Manual
Table Of Contents
- Operating & Maintaining the Connex500/350 3-D Printer
- Starting the Connex Printer
- Loading Model and Support Cartridges
- Producing Models
- Resuming Production After Printing has Stopped
- Changing the Model Material
- Keeping the Connex Printer in Idle Mode
- Shutting Down the Connex Printer
- Maintaining the Connex Printer
- Routine Maintenance Schedule
- Cleaning the Print Heads
- Pattern Test
- Improving Print Quality
- Cleaning and Replacing the Wiper
- Cleaning the Roller Waste Collector and Inspecting the Roller Scraper (Knife)
- Replacing the Roller Scraper (Knife)
- Aligning the Print Heads
- Calibrating Print Heads
- Replacing Print Heads
- Testing and Calibrating the UV Lamps
- Calibrating the Load Cells
- Replacing the Odor Filter
- Replacing the UV Lamps
- Built-in Tests
- Replacing the Waste Container
- Cleaning the Exterior Panels
- Handling Printed Models
DOC-13000 Rev. E 7–37
Connex500/350 User Guide
Thehead‐purgecycleruns,afterwhichtheWeightTestisprinted.
Figure 7-52: Printing Weight Test
15. 32samplesareprintedonthebuildtray,fourforeachoftheprint
heads.Thiscantakeupto55minutes.
16. Whenthefollowingscreenappears,opentheprintercover.Enterthe
datathatdescribestheconditionofeachprinthead,afterinspecting
eachoftheprintedsamples.
Figure 7-53: Weight Test Data Entry screen
a. Enterthenumberoffaulty(“missing”)nozzles.
FaultynozzlesareseeninWeightTestsamplesasamissingrowof
printedmaterial.Comparetheheightofthemissingrowwiththe
linesprintedonthe“missingnozzles”ruler.Enterthenumbernext
tothelinethatmostcloselymatchestheheightofthemissingrow
.
The layout of the data entry screen matches the printed samples on the
build tray. Enter the data for the sample indicated by in the screen.