User's Manual

Operating & Maintaining the Connex500/350 3-D Printer
7–28
DOC-13000 Rev. E
7. Returntherollerwastecollectortotheprintblockandscrewonthe
covering(seefigure 732onpage 727).
8. Loosenthescrewssecuringthesuctiontube.
Figure 7-35: Suction tube correctly positioned
9. Loweritsothattheholeinthepanelbehindthesuctiontubeisvisible,
andtightenthescrewstosecurethesuctiontube.
10. AttachtherightUVlampassemblytotheprintblockandreconnect
theUVpowerandfancables.
Replacing the
Roller Scraper
(Knife)
Youshouldreplacetherollerscraperblade:
after1,000hoursofprinting.
ifitdoesnoteffectivelykeeptherollerclean.
To replace the roller scraper:
1. Prepare—
anewrollerscraper(knife)(Kit01026S)
aPhillips1x75mmscrewdriver
M2.5andM2Allenkeys
2. RemovetherightUVlampandtherollerwastecollectorcovering(see
steps3to6onpage 726.)
3. Loosenthetwoscrewssecuringtherollerwastecollector andpullit
out.
Figure 7-36: Removing the roller waste collector
You should periodically test the effectiveness of the roller scraper when you
clean the roller waste collector. See “Cleaning the Roller Waste Collector
and Inspecting the Roller Scraper (Knife)” on page 25.