Table Of Contents
- Operating & Maintaining the Connex500/350 3-D Printer
- Starting the Connex Printer
- Loading Model and Support Cartridges
- Producing Models
- Resuming Production After Printing has Stopped
- Changing the Model Material
- Keeping the Connex Printer in Idle Mode
- Shutting Down the Connex Printer
- Maintaining the Connex Printer
- Routine Maintenance Schedule
- Cleaning the Print Heads
- Pattern Test
- Improving Print Quality
- Cleaning and Replacing the Wiper
- Cleaning the Roller Waste Collector and Inspecting the Roller Scraper (Knife)
- Replacing the Roller Scraper (Knife)
- Aligning the Print Heads
- Calibrating Print Heads
- Replacing Print Heads
- Testing and Calibrating the UV Lamps
- Calibrating the Load Cells
- Replacing the Odor Filter
- Replacing the UV Lamps
- Built-in Tests
- Replacing the Waste Container
- Cleaning the Exterior Panels
- Handling Printed Models
Operating & Maintaining the Connex500/350 3-D Printer
7–26
DOC-13000 Rev. E
3. RemovetherightUV‐lampassembly:
a. DisconnecttheUVpowercableandthefanpowercable.
Figure 7-30: Disconnecting the right UV assembly
b. RemovethescrewattachingtherightUVlamptotheprintblock,
andthenpullandliftuptheUVlamp.
4. Loosenthetwoscrewssecuringthesuctiontubeontheprintblock
Figure 7-31: Lifting the suction tube
5. Liftthesuctiontubetosecureitinaraisedposition.
6. Removethetwoscrewssecuringthecoveringoftherollerwaste
collectorandremoveit.
Fan power
connector
Power connector
Screw
Suction tube screws
Be very careful to save the covering screws. These are special screws, if
they are lost you need to order replacements.