User's Manual
Table Of Contents
- Operating & Maintaining the Connex500/350 3-D Printer
- Starting the Connex Printer
- Loading Model and Support Cartridges
- Producing Models
- Resuming Production After Printing has Stopped
- Changing the Model Material
- Keeping the Connex Printer in Idle Mode
- Shutting Down the Connex Printer
- Maintaining the Connex Printer
- Routine Maintenance Schedule
- Cleaning the Print Heads
- Pattern Test
- Improving Print Quality
- Cleaning and Replacing the Wiper
- Cleaning the Roller Waste Collector and Inspecting the Roller Scraper (Knife)
- Replacing the Roller Scraper (Knife)
- Aligning the Print Heads
- Calibrating Print Heads
- Replacing Print Heads
- Testing and Calibrating the UV Lamps
- Calibrating the Load Cells
- Replacing the Odor Filter
- Replacing the UV Lamps
- Built-in Tests
- Replacing the Waste Container
- Cleaning the Exterior Panels
- Handling Printed Models
Operating & Maintaining the Connex500/350 3-D Printer
7–22
DOC-13000 Rev. E
Figure 7-25: Sample Pattern Test
6. Carefullyinspectthetestpapertoseeiftherearemissinglines.
Toomanymissinglines,especiallyiftheyareinthesamearea,
indicatesthatthequalityofprintingwhenproducingmodelswillbe
poor.Ifthisisthecase,see“ImprovingPrintQuality,”below.
Note: Acceptable model quality is subjective, and depends on the type
and scale (size) of the models produced. As a rule, however, more than 10
missing lines in one area of a column is considered unacceptable.
Improving
Print Quality
Ifyoususpectthatprintqualityispoor,performthepatterntest(see
“PatternTest”onpage 7‐21).Iftheresultsarepoor,usethefollowing
proceduretoimproveprintquality.
If the results of the last pattern test are poor:
1. FromtheOptionsmenu,selectExecute Purge Sequence,orpressF4.
2. Intheconfirmationdialogbox,click
Yes.
Theprintheadsarepurgedofmodelandsupportmaterial,andthe
wiperremovesexcessmaterialfromthem.
3. Repeatthepurgesequence.
4. Performthepatterntest.
If the results of the pattern test are still poor:
1. Manuallycleantheprintheads(see“CleaningthePrintHeads”on
page 7‐19).
2. Performthepurgesequence.
3. Performthepatterntest.
If the results of the pattern test are still poor:
1. Carefullycleantheprintheadsagain,makingsurethereisnoresidue
leftonthem.
2. Performthepurgesequence.
3. Performthepatterntest.
If the results of the pattern test are still poor:
¾