Electrical Requirements
AC Power Requirements
• 50/60 Hz.
• Voltage: 100-132, 200-240 VAC.
Caution:
In regions with input power above 240 VAC, a step-down transformer must be
installed to the system.
• Current: 15/7A.
• The grounded electrical outlet must connect to either a Euro or a US power cord plug
(p
rovided in the Welcome Kit) and must be located within 2 m (80 inches) of the printer.
Caution:
A power cable is provided for connecting the printer to the AC electric source. Do not
use it with other equipment.
Operation of the printer outside this range is not re
commended; degradation of performance
and shortened component life expectancy will be experienced. Facilities who are unsure of
their power quality should contact their service provider.
Caution:
Do not use an extension cord or power strip; doing so can result in intermittent power
issues. Connect the power cord directly into the receptacle.
Workstation Requirements
For GrabCAD Print workstation requirements please visit:
http://help.grabcad.com/article/195-system-r
equirements-for-grabcad-print
.
While on the GrabCAD website, be sure to join the F120 GrabCAD community.
LAN Requirements
If utilizing a LAN connection for communication and file transfer functions, the LAN connection
is a 100 base T, Ethernet protocol, RJ45 connector. One 15 foot (4.57 m) CAT6, 10/100 base T
cable is supplied with the printer, located in the Welcome Kit. The printer will function in either
DHCP or Static IP configurations.
A LAN connection is not required however, as the prin
ter is also ca
pable of file transfer via a
Wi-Fi connection or a USB flash drive plugged into either of the printer’s USB ports. See the
F120 User Guide for detailed information and instructions on transferring files to the printer.