User Guide
http://onsemi.com
4
2. USER GUIDE
This section provides step-by-step manual on how to use the STR-DMS-NCV7694-GEVK. In general it consist of three boards:
- STR-DMS-NCV7694-GEVB (GazeT housing IR LED board)
- STR-DMS-CONTROL-GEVB (Control board to adjust Voltage and current on IR LEDs)
- STR-ASSISTED-RSL10-GEVB (RSL10 SoC based Strata interface module)
Connection of the modules when PWM flash taken from STR-ASSISTED-RSL10-GEVB
The STR-DMS-NCV7694-GEVK is delivered as platform that can operate as standalone evaluation kit. Using the Strata interface
and control board, one can adjust:
i. the Ton time (PWM flash) with fixed frequency 62Hz
ii. Output voltage of DCDC converter NCV890204
iii. LED current amplitude I_LED
Note: When operating from PWM flash out of Strata module, make sure that jumper CON4 is plugged
Fig. 1 CON4 jumper to be plugged when PWM flash signal taken from Strata Control board