Connection of the modules when PWM flash taken from Image Sensor
The STR-DMS-NCV7694-GEVK as platform can operate with Image sensor. Using the Strata interface and control board, one can
adjust:
i. Output voltage of DCDC converter NCV890204
ii. LED current amplitude I_LED
Image Sensor will serve for PWM Flash generation set out of the DevWare system.
Note: When operating with Image sensor, PWM flash out of Strata module is not used, make sure that jumper CON4 is
unplugged
Fig. 7 CON4 jumper to be un-plugged when PWM flash signal taken from Image Sensor
Please follow the connection steps as outlined in previous chapter. For PWM_Flash signal this is generated directly from camera
module (and not from Strata control board, hence CON4 jumper not assembled).
Make sure you have available Regulated Constant Voltage Power supply with current capability up to 10A (in case you connect
more modules). Connect up to two or three STR-DMS-NCV7694-GEVB GazeT modules to the GazeT image sensor module over