4.1 Cutting Mode Selection
1. Press ‘Mode’ selecon buon (15) unl the desired Cung Mode Indicator Light (16, 17 or 18) is
lit.
4
.1.1 Test Air
In ‘Test Air’ mode the compressed air control valve is open connuously. This is useful for tesng and
seng the air pressure without having to acvate the trigger circuit.
4
.1.2 Normal Cutting
This is the standard cung mode for cung.
4
.1.3 Perforated Cutting
This is the cung mode is used for cung perforated plate or expanded mesh. In this mode the plasma
arc will be maintained while the torch is passing over the holes or expansions.
If Normal Cung mode was used the plasma arc would exnguish when it reached each hole or
expansion.
4
.2 Amperage Adjustment
1. Rotate Amperage Knob (14) to desired amperage seng.
NOTE: In most applicaons maximum amperage will work best. On very thin material or delicate
applicaons you may wish to turn the amperage down.
Figure 5