Instruction Manual

4
.5 Error/Over Temperature Indicator Light
Error/Over Temperature Indicator Light (21) illuminates when duty cycle is exceeded and thermal
protecon is acvated. When thermal protecon is acvated, plasma cung output will be disabled
unl machines cools suciently and overload indicator lamp goes out.
This may also acvate if there are electronic circuit failure issues.
Figure 9
4
.6 Torch Error Light
The Torch Error Light (20) illuminates when there is an issue detected with torch system or air supply.
For safety and protecon of the operator and the torch, cung output is disabled when this is
illuminated.
Flashing light means that torch shield cap is not installed.
Connuous light means likely damaged or missing torch consumables or insucient air pressure
supply to the torch.
Figure 10
4.7 Cutting Active Light
The Cung Acve Light (19) illuminates when the cung power circuit is acvated.
Figure 11
11
www.strata.co.nz
ADVANCECUT 45