Operation Manual
installation 
Commissioning
Pressure test point
Use the oven burner. From inside the 
oven remove the burner cowl. Remove 
the small screw at the LHS of the burner 
cradle. Slide the burner to the left to ac-
cess the injector.
Connect suitable T-piece (incorporating 
a115injector)totheinjector.Connect
manometer to the T-piece, and turn oven 
control to full on to check pressure.
Replace in reverse order.
Burner aeration
Allburnershavexedaerationandno
adjustment is possible.
Pressure setting
See technical data.
Electrical systems check
In the event of an electrical fault the 
preliminary electrical system check (earth 
continuity, short circuit, polarity and resis-
tancetoearth)mustbecarriedout.
Ignition check
Ovenignition:
Push in and turn the main oven control 
knob anti clockwise to the ‘FULL ON’ 
position. The ignition system will spark 
automatically. Push in the control knob to 
ignite the gas. The sparking will stop. If 
after 15 seconds, the burner has not lit, 
turn off the oven and leave the compart-
ment door open. Wait at least one minute 
before a further attempt to ignite the 
burner.
Do not hold the control knob in for more 
than 15 seconds.
Turn the control knob clockwise to the 
required setting.
To turn off, return the control knob to the 
“off” position.