Operating Instructions and Installation Instructions
installation
CONNECT TO THE ELECTRICITY 
SUPPLY
WARNING: This appliance must be 
earthed. Only connect to the electrical 
mains terminal with the power switched 
off. The electrical mains terminal is live. 
Follow the terminal block connection 
schematic
Loose and inappropriate connections can 
make the terminal overheat.
Ensurethecableclampisttedcorrectly
and securely.
A device must be provided in the 
electrical installation which allows the 
appliance to be disconnected from the 
mains at all poles with a contact opening 
of at least 3mm.
We recommend that the appliance is con-
nected by a competent person who is a 
member of a “Competent Person Scheme” 
who will comply with the required local 
regulations.
Connection should be made with a suit-
able cable. 
• Firstly open the terminal block cover 
usingasmallatbladedscrewdriver
in the door release tabs shown below.
Door release tab
Cable clamp screw
Cable clamp ratchet
1
2
3
1
2
3
• Remove the cable clamp screw and 
release the cable clamp retaining 
arm.
Note;
The cable clamp has a ratchet type 
mechanism on the right hand side of the 
retaining arm.
• Strip the wires & connect to the 
terminalblockasappropriate:-
• Fit the cable clamp & secure with the 
screw provided.
• Close the terminal box, ensuring that 
the cover is closed and all screws are 
tight and in place.
Important: Ensure that you route all 
mains electrical cables well away from any 
adjacent heat source, such as the base of 
the hob an oven or grill.
4
5
Live 
Neutral
Earth
4
5
BROWN / L1
BLUE / N
GREEN/YELLOW / PE
230V.....240V
Terminal Block Connection