Operating Instructions and Installation Instructions

INSTALLATION
CONNECT TO THE ELECTRICITY SUP-
PLY
Warning:
This appliance must be
earthed.
This appliance is not intended to be oper-
ated by means of an external timer or
separate remote control system.
The appliance must be installed by a
competent electrician using a double
pole control unit of 32 ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance is con-
nected by a competent person who is a
member of a competent persons scheme.
1. Access to the mains terminal is gained
by opening the terminal block cover at
therearoftheappliance(useasmallat-
bladedscrewdriver).
2. Connection should be made with
6.0mm2exibletwinandearthcable.
3. First strip the wires, then push the
cable through the cable clamp in the
terminal block cover.
4. Connect the cable to the
terminal block and tighten the cable
clampscrew(seediagram).
5. Close the terminal box, ensuring that
the cover is engaged on the locking tabs.
Yourappliancewillbettedwithoneof
the terminal blocks below, Block A, Block
B, or Block C
Ifyourapplianceisttedwiththetermi-
nal block below, for multiphase appliances
please remove the links from terminals
L1, L2 and L3 only. Leave neutral links
ttedtoterminalsN4andN5.
L1
Cable clamp
Earth
(Green / Yellow
or sleeving)
PHASE 1
Neutral
N4
L2
L3
PHASE 2
PHASE 3
N5
Block C