5.5 Adjust the operating air controls to the maximum, or
start-up, setting and close the door.
5.6 Leave the fire to establish and develop a glowing firebed
(this may take 30 to 45min or more in some cases).
5.7 Once the fire is established refuel as described in Section 8.
Do not load fuel above the log guard and the secondary
combustion chamber at the back of the rebox, See
Diagram 15.
Wood
Multi-Fuel
Log bar
Log bar
Secondary Combustion Chamber
Secondary Combustion Chamber
15
5.8 Close the door and follow the instructions for Running the
Appliance.
Do not run with the door slightly open except for initial
lighting as this could cause over-ring and damage the
appliance.
6. Running the Appliance
Wood Burning Stove
6.1 There are several settings that can be used when burning
wood, see Diagram 16.
The air control slider is operated by pushing or pulling to
increase or decrease the air flow. Each position is indicated
by an indent 11mm apart.
16
OFF
Maximum Out
NOMINAL RUNNING
Smoke Control Setting
(If enabled)
MAXIMUM RUNNING
START UP
Maximum In
6.2 Start Up
Off
(Maximum Out)
Nominal Running
Smoke Control Setting
(if enabled)
Maximum Running
Start Up
(Maximum In)
17
UsetheStartUpsettingtoestablishthereandduringthe
initial moments of refuelling.
Do not run for long periods of time on this setting as this
couldoverretheapplianceordamagetheglass.
Oncethereisestablished:
— Move the control lever out.
The notched settings should be used as a guide.
The appliance can be burnt with the control anywhere along
its length.
6.3 Maximum Running
18
Off
(Maximum Out)
Nominal Running
Smoke Control Setting
(if enabled)
Maximum Running
Start Up
(Maximum In)
The Maximum Running setting allows the appliance to burn
at the maximum output when burning wood. Take care not to
overretheappliance.