Technical Appendix
Organisations authorised to certify competence in
the installation of domestic solid fuel appliances
(Competent Persons Scheme):
APHC - Association of Plumbing and Heating
Contractors (Certification) Ltd.
www.aphc.co.uk
BESCA - Building Engineering Services Competence
Accreditation Ltd.
www.besca.org.uk
HETAS - Heating Equipment Testing and Approval
Scheme Ltd.
www.hetas.co.uk
NAPIT - National Association of Professional
Inspectors and Testers Ltd.
www.napit.org.uk
NICEIC - NICEIC Group Ltd.
www.niceic.org.uk
HETAS Approved Chimney Sweeps:
NACS - The National Association of Chimney Sweeps
www.chimneyworks.co.uk
APICS - The Association of Master Chimney Sweeps Ltd.
www.apics.org
The Guild of Master Chimney Sweeps -
guildofmasterchimneysweeps.co.uk
5. Fitting Appliances On A Boat
5.1 If an appliance is to be fitted in a boat it must be done in
accordance with the latest edition of BS 8511 (Code of
Practice for the Installation of Solid Fuel Heating Appliances
on Boats). The Code covers the design, installation
and operation of solid fuel heating appliances that are
suitable for fitting into inland waterway boats, and gives
guidance on product selection, design considerations,
installation requirements, inspection and testing, as well as
maintenance and safe use tips.
5.2 Consideration should also be given to the requirements
of the Boat Safety Scheme (BSS) to ensure the boat's
insurance remains valid.
5.3 The appliance should only be installed by a competent
person with experience of the latest edition of BS 8511 and
the Boat Safety Scheme (BSS).
5.4 Secure the product to a suitably constructed non-
combustible hearth.
5.5 All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to enter the
boat. An electronic carbon monoxide detector conforming
to the latest edition of BSEN50292 must be fitted and
maintained.
5.6 Failure to safely install the appliance could endanger the
boat and persons on board.
Model
Vogue Midi
T Highline
Eco W
Vogue Midi
T Highline
Eco MF
Direct Efficiency Class A+ A
Direct Heat Output (kW) 5.00 5.00
Indirect Output (kW) - -
Energy Efficiency Index (EEI) 106 103
Useful Energy Efficiency at Nominal Heat Output 80% 78%
Safety Precautions
Product Fiche - Information Requirement for Solid Fuel Local Space Heater