Vogue Midi T Highline Ins…lation User Instructions

35
Installation Instructions
5.14 Undo the 4 nuts & screws securing the EN plate and remove,
see Diagram 23.
23
5.15 Position the DEFRA plate and fasten using the 4 nuts and
screws, see Diagram 24.
24
5.16 RettheAirSlidertotheundersideoftheappliancein
reverse order from 5.13.
5.17 The appliance can now be operated in a Smoke Control
area.
6. Secondary Air Control
The Secondary Air control is factory set to the optimum
setting for burning both wood and smokeless fuels. However,
if you are burning only one fuel type it can be adjusted as
shown to optimise the combustion for the chosen fuel:-
Wood Only - Position A (Open).
Smokeless Fuels Only - Position B (Closed).
WARNING: DO NOT modify the secondary air control
slider.
6.1 The Secondary Air Control is located on the back of the
appliance, see Diagram 25.
Secondary Air
Control
25
To adjust the Secondary Air Control:
6.2 Undo the nuts shown in Diagram 26.
Nut
A
B
26
Position B - Closed
Position A - Open