Vogue Midi T Highline Ins…lation User Instructions

31
Installation Instructions
3.8 Elevatethetopplatewhilsttheuepipeissealedwithre
cement.
When complete lower the top plate onto the appliance.
9
Cast top plate
(Shown elevated)
Appliance top
Seal collar
withre
cement
Flue Collar
A Typical Top Flue Pipe Installation
Connection to chimney as
detailed in Building Regulations
135˚Elbowwith
access cover
Flue Pipe x
612 long
600mm minimum
All Models
10
1000mm max
unsupported
4. Rear Flue Installation
Becausetheapplianceissuppliedfortopueexit,the
blanking plate will need to be moved to the top of the
appliance,thecastueblankaddedtothetopplate,andthe
additionalrearuecollaranduepipettedtotherear:
4.1 Tools required - cross-headed screw driver, 13mm A/F
spanner/socket wrench, hex key.
4.2 Tochangefromtoptorearexitue,reversetheuecollar
and blanking plate using the method detailed:
—Removethebafe.
—Removethetwoupperrebricks.
11
Blanking
Plate
Flue Collar Inner
Upper
Firebricks
Bafe
Flue Collar
4.3 To remove the ue collar lift off the Cast Top Plate and
remove the 4 M8 nuts from the M8 bolts. The collar will lift off
the top of the appliance.
12
Flue Collar
Appliance Top
Top Plate
M8 Nut
Cast Top Plate
Blanking Plate
Flue Collar
M8 Bolt