Vogue Midi T Highline Ins…lation User Instructions

24
Installation Checklist
Rear Wall
Side Wall
B
A
E
A
D
Parallel Position Clearances
No Combustible Wall in front of the appliance
Corner Position Clearances
B
A
A
D
D
Height above appliance
C
(Wall Height)
Distance to Non-combustible Materials
Distance of
Appliance to Wall (A)
Minimum Thickness
of wall (B)
Minimum Height of
Wall (C)
0mm - 50mm* 200mm Height of appliance +
300mm OR 1200mm
from the hearth (take
largest dimension)
51mm - 300mm 75mm
300mm+ No requirement No requirement
2
Note: Minimum distance to combustible material must be 450mm from any exposed single wall flue pipe.
80mm
Note: When installing
a Multi-fuel appliance
a minimum gap of
80mm must be left on
the Right Hand Side so
that the riddling tool
can be comfortably
engaged in the socket.
Combustible Materials
IF THE APPLIANCE IS TO BE INSTALLED IN A COMBUSTIBLE SETTING THE MINIMUM CLEARANCES CAN ONLY BE
ACHIEVED USING A TWIN WALL FLUE SYSTEM AND HEAT SHIELD, SEE HEAT SHIELD INSTRUCTIONS PM1347.
4.3 It is essential for safety to ensure the following clearances to combustible materials are maintained.