Vogue Midi T Highline Ins…lation User Instructions

21
Installation Checklist
2. Essential Information - Multi-fuel Stove
GENERAL
Model:
Vogue Midi T Highline
Midi T Highline
Nominal Heat Output
Wood kW 5.0
Solid Fuel kW 5.0
Efficiency
Wood % 78
Solid Fuel % 78
CO @ 13% O
2
Wood % 0.12
Solid Fuel % 0.11
Weight Multi-fuel stove Kg 123
Recommended Fuels
Wood
Seasoned Wood (less than 20% moisture content)
Solid Fuel
Briquette smokeless fuel suitable for closed appliances
(Ancit-Phuracite-Taybrite-Maxibrite-Homefire Ovals)
As tested to the requirements of EN 13240 for intermittent operation
FLUES
Flue/Chimney Size
May be reduced to 128mm (5") if
burning approved smokeless fuels or
burning wood in an appliance approved
for use in a DEFRA smoke control area
Without flue liner Round
(Diameter)
mm ‡153
inch 6
Without flue liner system (Square)
mm 135
inch
With Liner of Factory made system
(diameter)
installed in accordance with
manufacturers instructions
mm 150
inch 6
Flue/Chimney
minimum height**
All products
**must be 4.5m from the hearth
to the top of the flue, with
no horizontal sections and a
maximum of 4 bends. Bends
must have angles of less than 45
degrees from the vertical.
m 4.5
feet 15
Flue Draught
Min
mm Wg
1.0
Nominal 1.5
Max 2.0
Flue Gas Mass Flow
Wood g/s 4.3
Solid Fuel g/s 4.0
Flue Gas Temperature at Spigot/
Socket
Wood
o
C 303
Solid Fuel
o
C 278
Flue Outlet Size
(Top or Rear Option)
All
mm 128
inch 5
European Min Spec for Chimney Flue - T400 N2 D 3 G50
VENTILATION
A) Traditionally Built Homes
• Where leakage is greater than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW output over 5kW
B) Modern Construction Homes
• Where leakage is less than 5m
3
/hour/m
2
.
• Ventilation normally required = 550mm
2
per kW
A Additional Ventilation
mm2 None
cm2 None
in2 None
B Additional Ventilation
mm2 2750
cm2 27.5
in2 4.4
For full technical details on ventilation see Technical Appendix on Page 44