Vogue Midi T Highline Ins…lation User Instructions
19
Troubleshooting
Symptom Cause Solution
THE APPLIANCE
Rapid creosote build-up in the chimney Wet wood (over 20% moisture)
Use dry seasoned wood (less than 20%
moisture content). Operate at a high
temperature for short periods each time the
appliance is used to avoid large build-ups of
tars and creosotes
Tarcomingfromuejoints
Appliance operated at continuous low
temperatures
Operate at a high temperature for short
periods each time the appliance is used to
avoid large build-ups of tars and creosotes.
See user instructions for correct use of air
control
Using poor quality wood
Use dry seasoned wood (less than 20%
moisture content)
Strong pungent smell after the appliance is
lit
Appliance operated at continuous low
output
Operate at high output for short periods. See
user instructions for correct use of air control
Using poor quality wood
Use dry seasoned wood (less than 20%
moisture content)
Wind noise from the air control Highuedraught
Consult your installer for advice on suitable
uesystem
Dirtyrebricks Wet wood (over 20% moisture)
Use dry seasoned wood (less than 20%
moisture content)
Dirty glass Wet wood (over 20% moisture)
Use dry seasoned wood (less than 20%
moisture content)
Glass blackening
Using poor quality wood
Use dry seasoned wood (less than 20%
moisture content)
Lowuedraught
Consult your installer for advice on suitable
uesystem
Incorrect use of air control
See user instructions for correct use of air
control
Appliance operated at continuous low
temperatures
Operate at high output for short periods. See
user instructions for correct use of air control
FLUES
Theuesystemhastwomainfunctions:
- To safely remove the smoke, fumes and combustion gases from the building.
-Toprovideasufcientamountofuedraught(suction)intheappliancetoensuretherekeepsburning.
Theuedraughtiscausedbyrisinghotgaseswhentheapplianceislit.
Tarandcreosoteareamajorcauseofchimneyres.Iftheapplianceexperiencesproblemswithtarbuildupconsultachimneysweep
before continued use of the appliance.
For advise on the correction of persistent ue problems consult a qualied heating engineer before continuing to use the
appliance.