5.3 Light the paper or firelighters, see Diagram 10.
10
5.4 Leave the door slightly open as the fire establishes and the
glass warms to avoid build up of condensation.
5.5 Add larger pieces of wood.
Do not use full sized logs at this stage, build up gradually in
size. Too many logs may smother the fire.
Do not load fuel above the log guard and the secondary
combustion chamber at the back of the firebox,
see Diagram 11.
Log bar
Secondary
Combustion
Chamber
11
5.6 Close the door and follow the instructions for Running
the Appliance.
Do not run with the door slightly open except for initial
lighting as this could cause over-firing and damage the
appliance.
If the Smoke Control kit is disabled, a notch is visible when
the air control is pulled out, see Diagram 8. This is not visible
if the Smoke Control kit is enabled.
8
Side View
65
End of
Channel
4.4 To meet the requirements of a Smoke Control Area the
appliance MUST be operated correctly in order to minimise
the amount of smoke produced.
If this appliance is installed outside of a Smoke
Control Area then the Smoke Control kit can be
disabled to give more control over the lower burn
rates.
Any modifications to the kit should only be done by
a suitably qualified installer and must be done at
the time of installation.
These instructions must be left with the User.
5. Lighting the Appliance
5.1 For best results set air controls as shown, see Diagram 9.
Off
(Maximum Out)
Nominal Running
Smoke Control Setting
(if enabled)
Maximum Running
Start Up
(Maximum In)
9
5.2 Place firelighters or paper and dry kindling wood on the
base bricks.
A successful fire initially requires plenty of kindling to
establish a hot firebox and warm the chimney to aid flue
performance.
User Instructions