Vogue Installation User Instructions
6
2. Using the Appliance for the First Time
2.1 To allow the appliance to settle, and fixing glues and paint
to fully cure, operate the appliance at a low temperature for
first few days.
2.2 Do not touch the paint during the first period of use.
2.3 During this time the appliance may give off some unpleasant
odours. Keep the room well ventilated to avoid a build-up of
fumes.
2.4 Please be aware that, during use, rope seals may discolour.
This is normal.
3. Recommended Fuels
3.1 Wood Logs:
Burn only seasoned timber with a moisture content of less
than 20%. To ensure this allow cut wood to dry for 12 to 18
months.
Wood Length
Appliance Wood Length
Vogue
330mm
6
Poor quality timber:
— Causes low combustion efficiency
— Produces harmful condensation
— Reduces effectiveness of the airwash and life of the
appliance
Do not burn construction timber, painted, impregnated /
treated wood, manufactured board products or pallet wood.
3.2 Fuel consumption.
As tested at nominal heat output to the requirements of EN
13240: 2001 for intermittent operation:
Description
Fuel Consumption
Kg/hour
Wood
Vogue Wood 1.5
A number of factors can affect the performance of the
appliance. See Troubleshooting Section for details.
4. Smoke Control Kit
This appliance is supplied with a pre-tted smoke
control kit and has been independently tested to
PD6434 making it exempt from the controls that
generally apply in Smoke Control Areas.
THE SMOKE CONTROL KIT IS SUPPLIED DISABLED
AND MUST THEREFORE BE MODIFIED BEFORE
INSTALLATION IN ORDER FOR THE APPLIANCE
TO MEET THE REQUIREMENTS OF A SMOKE
CONTROL AREA AND MUST BE OPERATED
CORRECTLY TO MINIMISE THE AMOUNT OF
SMOKE PRODUCED.
If this appliance is installed outside of a Smoke Control
Area then the Smoke Control kit can be left disabled to
give more control over the lower burn rates.
Any modifications to the kit should only be done by
a suitably qualified installer and must be done at
the time of installation.
4.1 This appliance is suitable for use in a Smoke Control
Area when burning wood and following the instructions
for use specied in this manual but ONLY if the Smoke
Control kit has been enabled.
4.2 If the Smoke Control kit is enabled, the air control slider has
restricted movement and can only be pulled out to 60mm,
see Diagram 7.
The air control can not be shut down completely.
7
Side View
60
4.3 If the Smoke Control kit is disabled, the air control slider can
be pulled out to 65mm, the maximum position, see Diagram 7.
The air control can be shut down completely.
Getting Started/User Instructions