Vogue Installation User Instructions
22
Installation Instructions
3. Rear Flue Installation
Because the appliance is supplied for top flue exit, the
blanking plate will need to be moved to the top of the
appliance and the collar and flue pipe fitted to the rear:
3.1 Tools required - cross-headed screw driver, 13mm A/F
spanner/socket wrench.
3.2 To change from top to rear exit flue, reverse the flue collar
and blanking plate using the method detailed:
— Remove the upper and lower baffles.
— Remove the top fire bricks.
Flue Collar
9
Upper
Baffle
Lower
Baffle
Top Fire
bricks
Blanking
Plate
Flue Collar Inner
3.3 First remove the deflector plate.
— Use a 13mm A/F spanner/socket to remove 1 M8 half
nut from each of the front two studs. The flanged spacer
will drop down.
— Remove a further M8 nut from each front stud,
see Diagram 10, Detail A Front.
Appliance Top
Appliance Top
Flue Collar
Flue Collar
Flue Collar
Deflector Plate
Deflector Plate
Blanking Plate
Deflector Plate
M8 Half Nut
Flanged
Spacer
Flanged
Spacer
M8 Nut
M8 Nut
M8 Half Nut
M8 Half Nut
M8 Nut
Detail A Front
Detail B Back
Detail B
Detail A
10
Stove top
M8 Nut
M8x15 Hex
Head Screw
M8 Nut
Stove
Back
Flue
Collar
Flanged
Spacer
M8 Half Nut
M8 Half Nut
Deflector Plate
Blanking Plate
11
— Remove 1 M8 nut from each of the rear studs using a
13mm A/F spanner/socket.
The deflector plate will drop down inside the appliance,
see Diagram 10, Detail B Back.
3.4 Remove the blanking plate using a 13mm A/F Spanner/
Socket wrench to take off the 4 M8 half nuts from the inside
back plate of the appliance. Withdraw the blanking plate
from inside and remove the 4 M8x15 Hex head screws from
the back of the appliance.
3.5 To remove the flue collar remove the 4 M8 nuts front and
back. The collar will then drop down inside the appliance.
3.6 Fitting the flue collar and blanking plate for rear flue:
— Fit the blanking plate to the top flue outlet using
4 M8 nuts.
— Seal to the firebox using fire cement.
— Slide the deflector plate through the 4 studs on the
underside of the appliance top.
— Line up with the flue hole and secure in position using 2
M8 nuts onto the 2 front studs (reverse of removal).
— Fit the flue collar to the rear flue outlet using the 4 bolts
and half nuts from the cover plate.
— Seal to the firebox using fire cement, see Diagram 2.
— Secure the deflector plate in position by fitting the two M8
Nuts onto the rear studs.
— Slide the flanged spacers over the two front studs and
secure tightly using 2 M8 half nuts.
— Re-install 2 upper rear side bricks.
— Re-install upper and rear baffle.
Note: Upper rear central brick is not fitted if the
appliance is configured for Rear Flue option