Vogue Installation User Instructions

16
Installation Checklist
3. Minimum Dimensions - Hearth
3.1 These appliances can stand on a superficial hearth which is
a minimum of 12mm thick, see Diagram 1.
This is also referred to as a Floor Protector Plate or Floor
Protector.
1
225mm minimum
12mm
150mm
minimum
150mm min
150mm min
840mm minimum
840mm
minimum
Appliance
Decorative Hearth
Change in level to
mark safe perimeter
3.2 If this appliance is installed in an elevated setting it is
recommended to increase the 225mm hearth depth to safely
contain any falling logs or embers. The higher the appliance
is installed the deeper the hearth should be to avoid
scorched floor coverings.
4. Clearances
IMPORTANT: INSTALLATION MUST COMPLY WITH
CURRENT BUILDING REGULATIONS.
ENSURE THAT SUFFICIENT CLEARANCES
ARE PROVIDED BETWEEN THE FLUE PIPE
AND ANY COMBUSTIBLE MATERIALS IN THE
FIREPLACE IN ACCORDANCE WITH THE RULES IN
FORCE.
4.1 When installing a Vogue stove it is important to observe
the following clearances to both combustible and non-
combustible materials.
Also ensure that a clearance of 1 meter is maintained in
front of the appliance when operating.
Fireplace: Minimum Clearances Above
& to the Sides
Combustible Materials
Non-Combustible Materials
Floor
Hearth
A
A
F
D
2
B
Fireplace: Minimum Clearances to
the Rear
Combustible Materials
Non-Combustible Materials
Floor
Hearth
A
E
3
B
Non-Combustible Materials
4.2 All appliances will require some clearance between them
and any non-combustible materials to allow for either:
— Installation, servicing or accessing controls.
— Convection in order for the appliance to function properly.
Recommended: Minimum clearances for installation/
servicing/convection is:
Rear - 25mm Sides - 50mm Top - 100mm
NOTE: If the non-combustible surface is less than
200mm thick additional clearances may be required.
This requirement ensures that the non-combustible material
does not transmit excessive heat through the wall onto
combustible material which might be placed against it.
See Diagrams 2 & 3 (Fireplaces) & Diagram 4
(Freestanding) and table below.
Distance to Non-combustible Materials
Distance of
Appliance to Wall
(A)
Minimum
Thickness of wall
(B)
Minimum Height of
Wall (C)
0mm - 50mm* 200mm Height of appliance
+ 300mm OR
1200mm from the
hearth (take largest
dimension)
51mm - 300mm 75mm
300mm+ No requirement No requirement
England and Wales – Document J / Scotland - Part
F/Document J (Republic of Ireland only)