Vogue Installation User Instructions

17
Installation Checklist
Freestanding Installation
4
C
B
A
A
150
150
Non Combustible Material
Combustible Materials
4.3 It is essential for safety to ensure the following clearances to
combustible materials are maintained.
See Diagrams 2, 3 & 4 and table below.
Model D (side) E (Rear)* F (Above)
Vogue 550 700 N/A
* Note this distance can be reduced by the fitting of a heat shield
kit, check with your Stovax retailer for availability and clearances.
5. Optional Extras
Outside Air Kit
5.1 This appliance can be fitted with an optional kit to help bring
air directly into the appliance from outside. For installation
and operating procedures refer to the instructions supplied
with the Outside Air kit - Stovax Part No PM373.
Heat Shield
5.2 This appliance can be fitted with a heat shield in order to
decrease the distance the appliance can be installed from
a wall. This must be done at the time of installation. For
installation and operating procedures refer to the instructions
supplied with theHeat Shield - Stovax Part No PM1119.
Appliance Part No.
Vogue
RVN-MIDHSK