Studio Freestanding Installation User Instructions

7
If these Studio models are installed outside of a
Smoke Control Area then the Smoke Control kit can
be removed to give more control over the lower
burn rates.
Removing the kit should only be done by a suitably
qualified installer and must be done at the time of
installation.
These instructions must be left with the User.
5. Lighting the Appliance
IMPORTANT: Stovax provide gauntlet style gloves
for the users protection from heat and any sharp
edges when using the appliance.
For your safety ensure that gloves are always worn
when opening, operating, refuelling or handling
internal metalwork.
5.1 For best results set air controls as shown, see Diagram 9.
Air Wash: Fully Open
Primary Air: Fully Open
9
5.2 Place firelighters or paper and dry kindling wood on the
base bricks.
A successful fire initially requires plenty of kindling to
establish a hot firebox and warm the chimney to aid flue
performance.
5.3 Light the paper or firelighters, see Diagram 10.
5.4 Leave the door slightly open as the fire establishes and
the glass warms to avoid build up of condensation.
10
4. Smoke Control Kit
This section applies to the Studio products listed:
Product Code Appliance
RVFST-500 Studio Freestanding 500
RVFST-1HT Studio Freestanding 1
RVFST-2HT Studio Freestanding 2
4.1 TheStudiomodelslistedaresuppliedwithapre-ttedsmoke
control kit and have been independently tested to PD6434
making them exempt from the controls that generally apply in
Smoke Control Areas.
4.2 These models are suitable for use in a Smoke Control Area
when burning wood and following the instructions for use
speciedinthismanualbutONLYiftheSmokeKithasnot
been removed.
4.3 Iftted,theSmokeControlkitcanbeseeninthefollowing
locations, see Diagrams 7 & 8.
7
Airwash
Frame
Glass
Airwash
Restrictor
Gap between Inner
and Outer box
8
Primary Air
Gap between Inner
and Outer box
Door
Primary Air
Restrictor
4.4 To meet the requirements of a Smoke Control Area the
appliance MUST be operated correctly in order to minimise
the amount of smoke produced.
User Instructions