Studio Freestanding Installation User Instructions
33
Maintenance & Servicing
4B. Lubricating Door Hinges
- Studio 3 only
4b.1 If the operation of the door becomes stiff or fails to close
properly it may be necessary to apply grease to the door
hinge.
4b.2 Complete lubrication of the hinges as follows:
— Open the door fully.
— Use a small paint brush to add a small amount of high
temperature anti-seize grease (Stovax part number -
RVS-MEC10275) to points 'A' and 'B', see Diagram 4.
A
B
4
4b.3 Open and close the door a few times to work the grease into
the hinge to return it to smooth operation.
5A. Adjusting the Door Catch
- Studio 500, 1 & 2
5a.1 To maintain the safe use of your appliance you may need
to adjust the door catch to ensure the safe, correct closing
of the door. If the door hinges have been adjusted the door
catch may need adjustment.
5a.2 The catches are located at the top and the bottom of the
right side of the door.
Location
5
5a.3 The top and bottom catches will need to be adjusted
separately and in the same manner.
The catch block can move in two directions,
see Diagram 6, 7 & 8.
6
Side ways
adjustment
In and Out
adjustment
Sideways Adjustment
Using a 10mm A/F Spanner loosen the 2 nuts that hold the
catch block to the door.
Do not remove the nuts completely.
This will allow some movement left or right to suit.
Tighten the nuts and recheck the catch operation.
In and Out Adjustment
Loosening or tightening the M6 screw and the nuts on the
catch block will cause the catch to move in or out from the
door and allow the hook to gain better purchase on the door
rollers.
Do not remove screw or nuts completely.
5a.4 To move Door Catch in:
Loosen Nuts 1 & 2.
Wind screw IN until the Door Catch is in desired position.
Tighten Nuts 1 & 2 down to Catch Block.
7
View from above Appliance door
Move
Towards
Appliance
Catch
Catch Block
Nut 1:
Wind Out
Nut 2:
Wind Out
Screw:
Wind In