1. Installing the Appliance
Each installation is unique to the property so it is not possible
to give details to suit every setting. The installation must comply
with Building Regulations
and be made using "best practice"
construction methods
.
The clearance to combustible materials for the Stovax Studio
models is greatly different due to the higher temperatures that
the appliance can reach. Extra care must be taken when creating
a builders opening. Pay careful attention to the distance to
combustible materials recommended and ensure the housing for
the appliance is built from non-combustible material.
Many fireplace openings have a supporting lintel. Do not remove
without supporting the remaining structure of the building. Do not
support the structure with the appliance or the flue system.
1.1 Take care when installing the appliance. Careless
handling and use of tools can damage the finish and/or
area.
NOTE: If installing with an Outside Air Kit, and/or a
Heat Shield, please consult manuals PM732 and PM361
prior to installation.
2. Bolting the Appliance to the Hearth
2.1 The appliance must be fixed to the hearth. Use the 4 hearth
mount holes shown in Diagram 1.
Take care not to damage the hearth.
2.2 Position the appliance where required on the hearth and
mark the location of the 4 fixing holes in the outer box.
2.3 Drill the right sized holes into the hearth.
2.4 Use suitable fasteners to fix into place.
Fixing holes
Side runners
1
Inserting the inner box:
2.5 Slide the inner box into the outer box.
There is a roller assembly at the rear of the inner box
which locates in cutouts in the base of the outer box,
see Diagram 2.
This will require 2 people.
2
3. Top Flue Installation
3.1 Apply fire cement in to the faces shown prior to fitting the
inner collar, see Diagram 3.
Fire
Cement
3
3.2 Fit the inner flue collar using the 4 bolts ensuring the 2
longer bolts are at the front and recessed into the Flue
Collar, see Diagram 4.
All bolts must be finger tight only at this stage.
Recessed into
Inner Collar
Long bolts - front
Short bolts - rear
4
England and Wales – Document J / Scotland -
Part F/Document J (Republic of Ireland only)
the latest edition of BS 8303, BS EN 15287,
BS 7566