Riva F40 Avanti, Midi, Highline, Riva F40 Cube Multi-Fuel Free Standing Stove MODELS: RVF40AV, RVF40AVM, RVF40AVH, RVF40C User Instructions For Use in Great Britain and Eire This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions and in some cases the product may require modification. Contact Stovax to obtain further information. IMPORTANT Please read these instructions carefully before using the appliance.
FOR YOUR RECORDS To assist us in any Guarantee claim please complete the following information:- Stovax dealer appliance was purchased from Name: ..................................................................................................................................................................................... Address:..............................................................................................................................................................................
SERVICE RECORDS 1st SERVICE 2nd SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service Due: Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................................... Next Service Due: Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING INSTRUCTIONS THE INFORMATION GIVEN IN THIS MANUAL IS TYPICAL FOR ALL MODELS UNLESS STATED. Before using this appliance, please read these instructions fully. RIVA AVANTI 1. GENERAL 1.1 This stove is designed for domestic heating and should only be used for this purpose, and in accordance with the manufacturers operating instructions. It should be installed by a competent installer, in accordance with the relevant local and national regulations. 1.
OPERATING INSTRUCTIONS 1.10 ASHCOVER 1.11 AIR CONTROLS RIVA AVANTI RIVA AVANTI PR7168 PR7173 RIVA CUBE CLOSE OPEN CLOSE PR7170 PRIMARY AIR CONTROL Move air control as shown using the door tool. PR7095 To operate the ‘touch latch’ press the centre of the ashcover to open and close the cover. 5 OPEN PR7171 AIRWASH AIR CONTROL This control has a pre-set "indent ball" stop in the closed position "opti-burn" setting. If the control is pushed past this point the airwash will be fully closed.
OPERATING INSTRUCTIONS RIVA CUBE 1.12 DOOR HANDLE Lift to Open Remove PR7172 RIVA AVANTI To open and close the door use the tool provided as shown. PR7109 CLOSE OPEN PR7092 PRIMARY AIR CONTROL Lower the ashpan cover and move the air control as shown using the ashpan tool. OPEN Remove CLOSE Pull to Open PR7094 AIRWASH AIR CONTROL This control has a pre-set "indent ball" stop in the closed position "opti-burn" setting.
OPERATING INSTRUCTIONS 1.17 RIDDLING GRATE When burning solid fuel de-ash the firebed, using the riddling grate system as shown below. 3. BURNING WOOD RIVA AVANTI CLOSE CLOSE OPEN OPEN CLOSE PR7170 RIVA AVANTI PRIMARY AIR CONTROL OPEN PR7092 PRIMARY AIR CONTROL AIRWASH AIR CONTROL OPEN CLOSE PR7094 AIRWASH AIR CONTROL 3.1 Open the Airwash control fully and open the Primary air control to approximately 25% open. 3.
OPERATING INSTRUCTIONS 3.8 Allow the new logs to burn at high output for a few minutes before adjusting the burn rate with the Airwash control to the desired setting. It is best to refuel little and often to maintain clean and efficient burning. 3.9 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the appliance. 3.
OPERATING INSTRUCTIONS WARNING Do not use the door as a rest or support when refuelling or adjusting the air controls as this could cause permanent damage to the appliance. Riva Avanti 6. SEASONAL USE 6.1 If the stove is not to be used during the warmer periods of the year it is recommended to clean and service the stove, as detailed in the Maintenance and Servicing section. 6.
OPERATING INSTRUCTIONS 7.2 As heat can remain in the ash for a long period after use, care must be taken when removing and carrying the full ashpan. We suggest that the ashpan is carried using gloved hands. Or the ash is placed directly in to a Stovax Ash Caddie. (Stovax part number 4227) 7.3 When burning wood the quantity of ash will be smaller and may only need removal once every week. To do this, allow the fire to burn out and cool.
OPERATING INSTRUCTIONS stove to ensure that the fire is kept burning. Draught is caused by the rising hot air in the chimney when the Riva stove is lit. Symptoms of poor performance related to flue draught include: - If the Riva stove emits smoke into the room continuously close the air controls and allow the stove to go out, and ventilate the room to clear the fumes. Do not re-light the appliance until the cause of the problem is identified and rectified.
MAINTENANCE and SERVICING For parts and spares mentioned below, please see the Stovax Stove & Hearth Accessories catalogue. 1. GENERAL 4. ANNUAL SERVICE Before any cleaning is carried out, allow the stove to cool to avoid risk of burns. 1.1 We would recommend that your Riva stove be cleaned fully on a regular basis, according to the level of use. Attention should be given to cleaning the baffle system, flueways and removing ash.
MAINTENANCE and SERVICING approximately one day. This allows the adhesive to fully bond to the seal before use. These products, all available from you local Stovax dealer, along with regular maintenance and use of the correct fuels, will help you to keep your stove in the best possible condition. If you require more information about Stovax products visit our website www.stovax.com. 4.12 Lightly oil the door catch mechanism and hinge pins. Avoid getting oil on to the door seals and glass. 4.
MAINTENANCE and SERVICING 3 4 1 7 Lower Baffle 5.5 PR7099 8 PR7100 PR7100 5.6 The replacement of the system is the reverse of the previous operations. 5.7 It is important to remove and clean the baffle system to ensure the flue ways are clear of soot and debris to ensure the safe and efficient operation of the appliance. The frequency of cleaning will depend on the appliance operating conditions. 5.8 The baffle system is designed to give safe and efficient operation of the appliance.
MAINTENANCE and SERVICING 7. FITTING A NEW DOOR GLASS 7.3 Lie the door on a soft flat surface, to protect the glass and the paintwork RIVA AVANTI 7.4 Remove the old door rope seal and scrape old glue from the locating groove. Clean the locating groove with a clean dry cloth to remove all old dust and debris. 7.5 Using a 2.5mm A/F hexagon key, remove the exposed fixing screws in the rope seal locating groove, then remove the trim/frame. The old glass can then be lifted clear of the door.
MAINTENANCE and SERVICING 8.3 Squeeze a generous bead of fresh Thermic Seal glue into the rope locating groove. Do not glue over the screw heads. Press the new rope into the locating groove, placing the joint in the middle of the lower edge of the door. 9.3 Using a 13mm A/F spanner loosen the locking nut holding the catch block shown in diagram 11, and reposition to achieve the correct fit. This may need a trial and error approch to find the correct position. 8.
MAINTENANCE and SERVICING 10B. ADJUSTING DOOR HINGES RIVA CUBE 10A. ADJUSTING DOOR HINGES RIVA AVANTI (Tool required - 5mm A/F Hex socket key) (Tool required - 4mm A/F Hex socket key) 10.1 To maintain the safe use of your Riva stove, you may need to adjust the door hinges to ensure safe correct closing of the door. Complete this operating as follows. 10.1 To maintain the safe use of your Riva stove, you may need to adjust the door hinges to ensure safe correct closing of the door.
MAINTENANCE and SERVICING 12A. ADJUSTING ASHPAN COVER TOUCH LATCH - RIVA AVANTI 11A. ADJUSTING ASHPAN COVER HINGES RIVA AVANTI (Tool required - 2.5mm A/F Hex socket key) (Tool required - 2.5mm A/F Hex socket key) Fixing Screw Fixing Screw PR7188 PR7148 11B. ADJUSTING ASHPAN COVER HINGES RIVA CUBE 12B. ADJUSTING ASHPAN COVER TOUCH LATCH - RIVA CUBE Fixing Screw Fixing Screw PR7110 PR7111 11.
CARE OF YOUR RIVA F40 To help you get the best performance from your Riva and keep it in good condition, inside and out, Stovax offers a wide range of cleaning and maintenance products as well as a host of accessories to help you enjoy the maximum pleasure from your stove.
NOTES 21
NOTES 22
NOTES 23
Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.