Use and Care Manual

21
2A-9 Mount Storm Shell Back
Install E6 in top right location (leave small gap between screw head
and wall) use 10mm socket
Remove Storm Shell Back and drill on top right mark with 5/32”
wood drill bit 1.5” deep.
2A-8 Mount Storm Shell Back
E6
10mm
1.5”
5/32”