Owner manual
10 Installation
StorCase Technology, Inc. Ultra320 DE100 User's Guide - Rev. A00
NOTE: Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor
control options. Refer to the drive manufacturer's documentation for further in-
formation.
Open Open Motor spins up on "Power On"
Open Closed Motor spins up only if SCSI
"Start" command is received
Closed Open Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed Closed Reserved
Closed = Jumper installed
Open = Jumper removed
DYST RMST Function
1 ID0 SCSI ID
2 GND Ground
3 ID1 SCSI ID
4 GND Ground
5 ID2 SCSI ID
6 GND Ground
7 ID3 SCSI ID
8 GND Ground
9 FFAULT Fan Fault LED/Alarm Enable*
10 FFAULT Fan Fault LED/Alarm Enable*
11 SYNC Drive Synchronous Signal
12 GND Ground
13 RMST Remote Start (see Table 2)
14 GND Ground
15 DYST Delay Start (see Table 2)
16 GND Ground
17 RLED Remote LED Cathode
18 RLED Remote LED Anode
19 FAN1 Fan Signal**
20 FAN2 Fan Signal**
21 Reserved Reserved
22 Reserved Reserved
PIN Signal Function
Table 1: Option Pin Connector (W1) Signal Descriptions
Table 2: Option Pins 13-16 Drive Motor Control
* Jumper on Pins 9 & 10 required for Fan Fault LED/Alarm option.
** Jumper on Pins 19 & 20 required for Fan option.